Dual Tower Nitrogen Generator

Dual Tower Nitrogen Generator

A dual tower nitrogen generator separates nitrogen from compressed air for on-site supply, with matched pre-treatment, automatic cycling and oxygen monitoring for stable industrial operation and safe reliable daily use.
Send Inquiry
Product Introduction

This dual tower nitrogen generator is intended for plants that need nitrogen at the point of use rather than delivered cylinders or liquid. It separates nitrogen from compressed air by pressure swing adsorption (PSA) using carbon molecular sieve (CMS). The two adsorber vessels alternate between adsorption and regeneration, so gas production continues while the offline bed is regenerated. Standard capacity is roughly 5–2,000 Nm³/h, with purity from 95% to 99.999%, depending on flow, pressure and configuration. Outlet pressure is normally adjustable within 0.1–0.8 MPa; a booster can be added when the process needs higher pressure. The unit should not be treated as a generic package. Purity, flow, dew point and pressure have to be matched to the actual process, otherwise the system may run outside its stable range.

 

Working principle

In a dual tower nitrogen generator, compressed air first passes through a refrigerated dryer and filters to remove water, oil and dust. Clean air enters the active adsorber, where CMS preferentially adsorbs oxygen, moisture and carbon dioxide. Nitrogen passes to the buffer tank. When the bed approaches its working limit, the PLC switches flow to the second tower and depressurises the first tower for regeneration. Automatic valves control the cycle, an oxygen analyzer monitors product purity, and the control cabinet records alarms and operating data. Pre-treatment deserves close attention. Oil and water carryover reduce sieve life and can cause dew-point problems that are difficult to correct later.

 

Design and pre-treatment

Each dual tower nitrogen generator should be selected around the actual duty cycle, not only the nameplate flow. Confirm required purity, flow, inlet pressure, outlet pressure, allowable dew point, ambient temperature, altitude and power supply. A typical system includes the air compressor interface, dryer, filters, air buffer tank, adsorber vessels, nitrogen buffer tank, oxygen analyzer, PLC, touchscreen and automatic valves. Optional items include boosters, high-purity post-treatment, remote monitoring and duplicate analyzers. Valve reliability and correct sieve filling have a direct effect on long-term performance. The installation area should be ventilated, above freezing, and allow service access to filters, valves and analyzers.

Typical data to confirm before order:

  • Purity: 95–99.999%
  • Flow: 5–2,000 Nm³/h
  • Inlet pressure: 0.6–0.8 MPa
  • Outlet pressure: 0.1–0.8 MPa, booster optional
  • Dew point: -40°C to -70°C depending on configuration
  • Control: PLC with touchscreen and automatic cycling
  • Analyzer: online oxygen analyzer with alarm
  • Utilities: stable power supply and clean compressed air

 

Typical applications

A dual tower nitrogen generator handles continuous or recurring batch demand. It serves laser cutting, food and beverage packaging, electronics assembly, pharmaceutical blanketing, chemical processing, metallurgy, and tire inflation. Set purity/dew point for packaging format, shelf life, and sensitive assembly; keep flow/pressure steady for laser cutting; add peak/purge margin for chemical blanketing; prevent oil carryover before process connection; and review low-demand cycling, which can affect stability and valve life.

 

Selection & installation

For a dual tower nitrogen generator, specify duty (Nm³/h or m³/h), target quality, pressures, dew point, power, and site constraints. Check feed air and buffer space. At startup, prove leak-tightness, valve cycling, output, and alarms. Service filters, dryer, analyzer, and valves. Trend readings to catch drift; if load changes, reassess cycle and buffer volume before resetting.

 

Shenger Gas designs PSA nitrogen solutions around actual site conditions, with each dual tower nitrogen generator supported by pretreatment, buffer tanks, oxygen analysis, PLC controls and commissioning. For technical review, share purity, flow, pressure and application details.

 

01

02

03

04

05

06

Hot Tags: dual tower nitrogen generator, China dual tower nitrogen generator manufacturers, suppliers, factory

Send Inquiry

Home

Phone

E-mail

Inquiry