Cryogenic air separation is a key technology for obtaining gases such as high-purity oxygen and nitrogen in industrial gas production. During this process, liquid oxygen usually contains trace impurities, which not only affect the purity of the product, but may also bring safety hazards. To ensure the high quality and safety of the final product, it is crucial to take effective measures to remove miscellaneously. This article will discuss in detail the common impurities of liquid oxygen in cryogenic air separation and its removal methods based on relevant specific data.

 

info-4032-3024

 

Common impurities and their hazards in liquid oxygen

1. Hydrocarbons: Studies have shown that in untreated liquid oxygen, the concentration of acetylene can be as high as 5ppm to 20ppm. Considering the explosion limit range of acetylene is 2.5% to 80%, even trace amounts of existence can cause serious accidents. Therefore, for liquid oxygen containing more than 1 ppm of acetylene, strict removal measures must be taken.

2. Carbon dioxide and moisture: Although the cryogenic process can effectively remove most of the moisture and carbon dioxide, trace residues may still occur in some cases. For example, when the relative humidity in the air reaches 70%, after preliminary cooling, the moisture content in liquid oxygen may reach 10 ppb to 100 ppb. The residual amount of carbon dioxide may reach about 5ppm. These substances form solid particles at low temperatures, increasing the risk of equipment failure.

3. Oil steam and other volatile organic compounds: volatilization from compressor lubricating oil or other mechanical components. The concentration of such impurities in liquid oxygen is usually less than 1 ppm. However, even such low concentrations are sufficient to reduce oxygen purity and increase combustion risk.

 

The importance of liquid oxygen removal

According to industry standards, the purity requirement of medical oxygen reaches at least 99.5%, while the purity requirement of industrial high-purity oxygen is higher, usually 99.999%. The presence of any impurities will significantly affect the purity of oxygen, which will in turn affect the use effect. In addition, according to the U.S. Occupational Safety and Health Administration (OSHA), safety accidents caused by impurities in liquid oxygen account for nearly 15% of all ASU-related accidents.

 

Liquid oxygen removal method and data support

1. Activated carbon adsorption method: Experiments show that using high-quality activated carbon to treat liquid oxygen can reduce the concentration of hydrocarbons below 0.1ppm. This is mainly because activated carbon has a huge specific surface area (up to 1000m²/g) and can effectively adsorb various organic impurities.

2. Molecular sieve purification technology: Molecular sieve has extremely high selective adsorption ability to carbon dioxide and moisture. For example, the 4A molecular sieve can reduce the carbon dioxide concentration in liquid oxygen from 5 ppm to below 0.1 ppm under -183°C, and the moisture content can be controlled within 1 ppb.

3. Distillation tower optimization: By adjusting the operating parameters of the distillation tower, such as increasing the reflux ratio from the original 3:1 to 5:1, the impurity concentration in the top product can be significantly reduced. Taking a large ASU as an example, this improvement reduces the total impurity content in liquid oxygen by about 60%.

4. Online monitoring and control system: The online monitoring system equipped by modern ASU devices can monitor the impurity content in liquid oxygen in real time, and the error range is controlled within ±0.01ppm. Once an exceeding standard is detected, the system will automatically adjust the process parameters or start the emergency handling procedure to ensure product quality.

5. Pretreatment measures: Use high-efficiency filters to remove dust particles in the air, and its efficiency can reach 99.99%, effectively preventing external pollutants from entering the ASU system; freeze-dryer can reduce the air dew point temperature to below -40℃, greatly reducing the moisture content entering the system.

 

Liquid oxygen decompression is not only a key step to improve product purity, but also an important link in ensuring safe production. By scientifically and rationally applying a variety of impurity removal technologies such as activated carbon adsorption, molecular sieve purification, distillation tower optimization, etc., and combining with advanced online monitoring and control systems, the liquid oxygen quality in cryogenic air separation can be significantly improved to meet the needs of different fields. In the future, with the continuous development of new materials and new technologies, liquid oxygen removal technology will also be increasingly improved, providing purer and safer oxygen resources for various industries.