In the operation and management of a cryogenic air separation unit, daily inspection is a basic routine that keeps equipment stable and product purity within specification. In long-term equipment operation and maintenance practice, Shenger Gas has found that whether a cryogenic air separation system can maintain efficient operation over a long period depends largely on how well operators handle inspection details. Cryogenic air separation equipment involves low-temperature distillation, heat exchange, compression and several other process units. Inspection is not a simple walk-around; it is a focused and logical confirmation of each key condition. The following sections outline the core daily inspection contents for cryogenic air separation operators from a practical operating point of view.

Cold Box and Insulation System Inspection
The cold box is the core area of cryogenic air separation. During inspection, first check for frost or condensation on the outer wall of the cold box. Local frost often indicates moisture ingress in the insulation or a cold loss, and the location and extent should be recorded promptly. The operator should check whether the breather port at the top of the cold box is clear, so that abnormal pressure in the insulation gas seal does not allow moist air to enter. At the same time, confirm that the cold box foundation temperature and the temperature points at each layer inside the cold box are within the normal range and that the temperature gradient is stable. Cryogenic air separation equipment places high demands on insulation integrity. Good insulation directly affects system energy consumption and operating stability, and it is an important support for keeping cryogenic air separation products economical in long-term operation.
Distillation Column and Separation Performance Inspection
The inspection focus of the distillation column is liquid level, resistance and product purity trend. The operator should check whether the liquid levels in the upper and lower columns are stable, whether the liquid air and liquid nitrogen levels are within process control limits, and avoid levels that are too high and flood the packing or too low and cause uneven gas-liquid distribution. Column resistance is an important reference for judging the working state of the packing layer. An abnormal increase in resistance may indicate flooding or blockage; a decrease requires attention to reflux ratio and product purity changes. Online analyzer readings should be recorded at regular intervals. When oxygen and nitrogen product purity fluctuates slightly, the operator should make a combined judgment based on liquid level, resistance and reflux ratio. The advantages of cryogenic air separation in separation accuracy and product purity are built on stable and controllable distillation conditions. The operator's sensitivity to these parameters during inspection directly affects final gas quality.
Heat Exchanger and Temperature Difference Control Inspection
Inspection of main heat exchangers, subcoolers and other heat exchange equipment mainly centers on temperature difference and pressure differential. The operator should confirm that the inlet and outlet temperatures of each channel match the design conditions. Excessive deviation in temperature difference often reflects reduced heat exchange efficiency or local channel blockage. Pressure differential monitoring is equally critical, especially for switching-type heat exchangers or plate-fin heat exchangers. When pressure differential rises, the operator should promptly check for moisture and carbon dioxide carryover. Cryogenic air separation equipment has a compact heat exchange system design and high cold recovery efficiency. Only by keeping temperature difference and pressure differential within reasonable ranges during daily inspection can this efficient heat exchange structure perform as intended.
Compressor and Expander Unit Inspection
Compressors and expanders are the power and cold source of cryogenic air separation. During inspection, focus on unit vibration, bearing temperature, lube oil pressure and oil temperature, listen for smooth running sound, and check whether seal gas pressure is normal. On the expander side, confirm that speed is stable, clearance pressure is normal, and pre-inlet temperature meets process requirements to avoid liquid carryover operation. Compressor cooling water inlet and outlet temperatures and flow should also be included in inspection records; insufficient cooling directly affects discharge temperature and energy consumption. Cryogenic air separation equipment emphasizes reliability in unit configuration and operating match. Careful inspection of these rotating machines by operators is key to ensuring long-cycle continuous operation of the entire air separation unit.
Purification System and Switching Valve Inspection
The inspection focus of the molecular sieve purification system is switching cycle, regeneration temperature and switching valve action. The operator should confirm that the regeneration heater outlet temperature and cold blow temperature follow the curve, and whether the switching valves open and close in place without signs of internal leakage. Poor purification system performance will allow moisture and carbon dioxide to enter the cold box and cause freezing blockage. Therefore, during inspection, special attention should be paid to switching pressure differential and outlet gas dew point trend. Cryogenic air separation has strict requirements for feed gas purification. Stable switching in the purification section is a precondition for long-term safe operation of the cold box.
Instrument and Safety Interlock Inspection
Field instruments and interlock status are parts that cannot be ignored in inspection. The operator should check whether the readings of key pressure, temperature and liquid level transmitters are consistent with local gauges, whether alarm records are abnormal, and whether safety valves and vent valves are in the correct position. Cryogenic air separation equipment has a relatively high degree of automation. Interlock protection is the bottom line for safe equipment operation. During inspection, confirming normal instrument signals and correct interlock activation is responsible both for the equipment and for the operator's own safety.
The daily inspection work of cryogenic air separation operators may look like repeated field confirmation, but in practice it runs through equipment operating status judgment, process parameter verification and safety hazard identification. In the design and operation support of cryogenic air separation equipment, Shenger Gas always values the operability of inspection procedures, so that operators can grasp the real equipment status in time through a clear inspection route. The efficiency, stability and long service life of a cryogenic air separation system often lie in these daily inspection details.