Air separation equipment startup guide

As a key device for separating gases such as oxygen and nitrogen from the air, air separation equipment is widely used in many fields such as metallurgy, chemical industry, and medical care. Correctly starting the air-dividing equipment can not only shorten the startup time and reduce energy consumption, but also ensure the stable operation of the equipment and extend the service life. The following will introduce the key points of the air separation equipment startup guide in detail from pre-start preparation, startup process, and other aspects. I hope it can help you.

 

info-4032-3024

 

Comprehensive inspection and preparation before starting

Before starting the air separation equipment, a comprehensive and detailed inspection must be carried out. Check the appearance of the equipment to see if there are any abnormalities such as damage, deformation, etc. For each connection part of the equipment, it is necessary to confirm whether the connection is firm, whether it is loose, whether the seal is good, and to avoid gas leakage. At the same time, check the electrical system and instrument control system of the equipment to ensure that each instrument is displayed accurately and the control function is normal.

It is also necessary to check whether the opening and closing status of each valve meets the starting requirements. For example, the status of important valves such as air inlet valves, product air outlet valves must be confirmed strictly in accordance with operating procedures. Check the lubrication system of the equipment to ensure that the quality and quantity of the lubricating oil meet the requirements and that the lubricating pipeline is unobstructed.

Before starting the air-separation equipment, it is necessary to ensure the normal operation of supporting facilities. For example, the cooling water pump must be able to provide a stable cooling water volume, and the pressure must reach 0.3 - 0.5MPa to ensure the cooling effect of the equipment. The power supply system must also be stable and reliable, and the voltage fluctuation range must be controlled within ±5% to avoid the normal start of the equipment due to voltage abnormalities.

 

An orderly startup process

1. Start the air compression system: First start the air compressor, suck the air in and compress it to 0.5 - 1.0MPa. During the compression process, pay close attention to the operating parameters of the compressor, such as the exhaust temperature, which should generally be controlled at 100-120℃ to prevent equipment failure due to excessive temperature. At the same time, the compressed air is initially purified to remove dust, impurities, etc.

Pre-cooling system starts: The compressed and initially purified air enters the pre-cooling system and reduces the air temperature to 10 - 15°C by exchanging heat with the cooling water. During this process, the flow rate and temperature of the cooling water must be adjusted to ensure that the air can be fully cooled and to improve the subsequent separation effect.

2. Purification system starts: The pre-cooled air enters the purification system and absorbs impurities such as moisture, carbon dioxide and other impurities in the air through the adsorbent. Generally, the adsorption period of the adsorbent is 4-8 hours, and regeneration is required after the expiration to restore its adsorption capacity.

3. Fractionation tower starts: The purified air enters the fractionation tower, and the separation of gases such as oxygen and nitrogen through multiple condensation and evaporation processes in the tower. When starting the fractionation column, the pressure and temperature inside the column must be controlled. Generally speaking, the lower tower pressure is maintained at 0.5 - 0.6MPa, the upper tower pressure is 0.13 - 0.15MPa, and the temperature in the tower is adjusted according to the boiling point of different gases.

 

Key considerations for starting the process

1. During the start-up of the air-separation equipment, the monitoring and adjustment of various parameters is crucial. It is necessary to monitor the air flow in real time and make reasonable adjustments based on the equipment load. The general air flow fluctuation range should be controlled within ±5%. Pay close attention to the pressure and temperature parameters of the equipment. Once abnormalities occur, the causes must be analyzed in time and corresponding measures must be taken.

2. During the process, a comprehensive inspection of the operating status of the equipment must be carried out. Check whether the equipment has abnormal vibration and noise, and whether there is any leakage in each connection area. If an abnormality is found, the machine must be shut down and troubleshooted immediately, and then the fault is eliminated before starting.

3. In addition, starting the air-dividing equipment is a gradual process and you should not be rushing to achieve success. At each stage, we must ensure that the equipment is running stably before proceeding with the next step. For example, after the fractionation tower is started, it needs to operate stably for 2-4 hours. After the working conditions in the tower are stable, then the product gas is extracted.

 

The air separation equipment startup guide can achieve safe and efficient start of air separation equipment by strictly following the above steps and performing various monitoring and adjustments during the startup process, laying a solid foundation for subsequent stable production, and giving full play to the important role of air separation equipment in various industries.